Automatic Out-of-step Protection of Synchronous Motor Supplied by Converter

机译:变频器提供的同步电动机的自动失步保护

获取原文

摘要

The paper deals with out-of-step protection of synchronous motor. Synchronous motor supplied by converter works in wide range of speed, and faces disturbance and acute change of load torque. The out-of step is frequently occurs, and damages the motor, affects on related process. The problem can be solved by adjusting supplied voltage according to the calculated load angle. The load angle can not be measured in working condition. But it can be calculated from stator voltage, current, and power factor which can be easily measured. The research discloses the inherent relations among the stator voltage, current, power factor, and load angle using phase graph under steady state adjustable voltage. Based on the relationship of the quantities, it proposes a scheme of automatic out-of-step protection. The scheme bas been simulated on a synchronous motor. The simulation results verify the validity and feasibility of the proposition.
机译:本文讨论了同步电动机的失步保护。变频器提供的同步电动机工作在很宽的转速范围内,并且会受到干扰和负载转矩的急剧变化。失步经常发生,并损坏电机,影响相关过程。可以通过根据计算出的负载角度调整供电电压来解决该问题。在工作状态下无法测量负载角。但是可以根据定子电压,电流和功率因数轻松计算得出。该研究利用相位图在稳态可调电压下揭示了定子电压,电流,功率因数和负载角之间的固有关系。基于数量的关系,提出了一种自动失步保护的方案。该方案基于同步电动机进行了仿真。仿真结果验证了该命题的有效性和可行性。