Experimental Study on Characteristics of Trans-critical Heat Pump Water Heater Using Refrigerant HFCI25

机译:制冷剂HFCI25的超临界热泵热水器特性试验研究。

获取原文

摘要

With continuous increase of energy consumption and constant strength of environmental protection, the moderate and high temperature heat pump technology has been paid more and more attention, and the study on it is one of the most attractive fields. Recently, the researches on moderate and high temperature heat pump have been concentrated on alternative refrigerants and system matching, where heat pumps using refrigerant HFC125 seem to be promising. In order to evaluate the performance of the heat pump using refrigerant HFC125, an experimental rig of de-inverter heat pump water heater was designed and set up, and the experimental study on trans-critical heat pump water heater using refrigerant HFC125 was performed so as to investigate its system performance. The relationship between COP and frequency of compressor was analyzed. It is found that there is an optimum frequency when the system runs at 95Hz. Then, case study at 95Hz, the evaporation pressure, condensation water temperature rise, discharge temperature, were discussed. Finally, the COP of HFC125 trans-critical cycle was compared with R410 sub-critical heat pump at the same conditions. The results indicate that there is an optimum COP when the compressor runs at 95Hz; the system COP shows an increasing tendency with the decrease of condensation pressure and compressor ratio while the evaporation pressure keeps invariant, and the COP decreases rapidly when cooling water temperature rises over 47.5°C. Compared with R410A sub-critical cycle, the COP of HFC125 trans-critical cycle significantly increases by an average of 12%.
机译:随着能耗的不断增加和环境保护的不断提高,中高温热泵技术越来越受到人们的重视,对其研究是最有吸引力的领域之一。最近,对中高温热泵的研究集中在替代制冷剂和系统匹配方面,其中使用制冷剂HFC125的热泵似乎很有希望。为了评估使用制冷剂HFC125的热泵的性能,设计并建立了逆变器热泵热水器的实验平台,并进行了使用制冷剂HFC125的跨临界热泵热水器的实验研究,以期调查其系统性能。分析了COP与压缩机频率之间的关系。发现在系统以95Hz运行时存在最佳频率。然后,以95Hz为例,讨论了蒸发压力,冷凝水温升,排放温度。最后,在相同条件下,将HFC125跨临界循环的COP与R410亚临界热泵进行了比较。结果表明,当压缩机以95Hz运行时,COP最佳。随着冷凝压力和压缩机比的减小,系统COP呈增加趋势,而蒸发压力保持不变,当冷却水温度升高到47.5°C以上时,COP迅速下降。与R410A次临界循环相比,HFC125次临界循环的COP显着提高了12%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号