The results of acid-soluble aluminum (Als)in steel tested by spark discharge optical emission spectrometry (OES),using either peak integration method spectral (PIMS)or pulse discrimination analysis (PDA),sometimes show deviation with wet chemical analysis results.Moreover,these deviations usually haven't much orderliness apparently.In this thesis,the relation between this deviation and the size of AlN precipitate in steel was demonstrated,according to our experiments and theoretical analysis.It's proved that the bigger particle size of AIN precipitate is in steel,the larger deviation of Als analysis result will be.Especially,the deviation of Als analysis results could be overlooked when the size of AlN precipitate is less than 300 nm.Finally,it is proposed that some points should be concerned when spark discharge OES is used to analyze Als in steel.
机译:通过火花放电光发射光谱法(OES)测试钢酸溶铝(ALS)的结果,使用峰积分法谱(PIM)或脉冲辨别分析(PDA),有时显示偏差与湿化学分析结果.Oroute ,这些偏差通常显然没有多大秩序。本文根据我们的实验和理论分析,证明了这种偏差与AlN沉淀物的沉淀物之间的关系。这证明了AIN沉淀的更大粒径是在钢中,ALS分析结果的较大偏差将是。特别地,当Aln沉淀物的尺寸小于300nm时,可以忽略Als分析结果的偏差。最后,提出了一些点应该在火花放电时关注OES用于分析钢中的ALS。