首页> 外文会议>ASME turbo expo >TEST RESULTS FROM THE ADVANCED HUMID AIR TURBINE SYSTEM PILOT PLANT - PART 1: OVERALL PERFORMANCE
【24h】

TEST RESULTS FROM THE ADVANCED HUMID AIR TURBINE SYSTEM PILOT PLANT - PART 1: OVERALL PERFORMANCE

机译:先进的湿式空气涡轮系统试验装置的测试结果-第1部分:总体性能

获取原文

摘要

The AHAT (advanced humid air turbine) system is based on a recuperated cycle using high-humidity air. This system improves thermal efficiency by using the high-humidity air as working gas.After many studies and elemental tests, a 4MW-class pilot plant was planned and built in order to verify feasibility of the AHAT system from the viewpoints of heat cycle characteristic and engineering. This plant consists of a gas turbine, a recuperator, a humidification tower, a water recovery system, an economizer, and other components. The gas turbine consists of a two-stage centrifugal compressor (pressure ratio of 8), a reverse-flow type single-can combustor, and a two-stage axial-flow turbine.In overall performance tests, the plant thermal efficiency exceeded 40%LHV.
机译:AHAT(先进的湿空气涡轮机)系统基于使用高湿空气的换热循环。该系统通过使用高湿空气作为工作气体来提高热效率。 经过大量研究和元素测试,计划并建造了一个4MW级的中试工厂,以从热循环特性和工程学角度验证AHAT系统的可行性。该工厂由燃气轮机,同流换热器,加湿塔,水回收系统,省煤器和其他组件组成。该燃气轮机由两级离心压缩机(压力比为8),逆流式单罐燃烧室和两级轴流式涡轮机组成。 在总体性能测试中,工厂的热效率超过40%LHV。