Pseudo-Static Test of Mixed Connections Between Steel Columns and Concrete Columns in Pudong (Shanghai) International Airport Terminal 2

机译:浦东(上海)国际机场第二航站楼钢柱与混凝土柱混合连接的拟静力试验

获取原文

摘要

Mixed columns, consisting of a steel upper portion and a concrete lower portion, were used in the construction of Pudong International Airport Terminal 2. Two types of joints were designed for connections between the steel roof and concrete columns. The first is a cast steel bearing, connecting inclined steel branches and the supporting concrete member; the second is a direct embedment of the inclined steel branch into the concrete column.In order to evaluate the mechanical behavior and reliability of these mixed connections, pseudo-static tests were carried out at Tongji University. Results and conclusions from this investigation include: 1) cracking and spalling were observed at the top of the concrete columns due to the moment applied by the upper steel columns and abrupt variation of column stiffness near the joint. Additional stirrups or an exterior steel tube are suggested to enhance shear capacity and improve confinement of the outer concrete. 2) Damage occurring at the bottom of the steel column could be attributed to the modulus of elasticity and yield strength of the steel both being decreased about 10% in the Heat Affected Zone (HAZ) as well as higher than expected strength of the cast steel. The damage observed near the butt weld showed great similarity to that of steel structures in the Kobe earthquake 1995. 3) A potentially critically damaged section was identified in the cast steel bearing based on the numerical and experimental results, however it remained undamaged in the test. Since the strength of the cast material is more inconsistent than hot rolled steel; a larger variance will be used to for the design strength. Therefore, the actual capacity of the cast steel bearing is more likely to be under-estimated and the performance of the cast steel may not be as expected in the original design. 4) Additionally, based on the analyses of loading transfer mechanism and calculation of elastic rotational stiffness with respect to cast steel bearings, mechanical behavior and deformation capacity of the bearings were investigated. A component of displacement at the top of steel columns was examined as well.
机译:浦东国际机场2号航站楼的建造使用了由钢制上部和混凝土下部组成的混合柱。设计了两种类型的接头,用于钢顶和混凝土柱之间的连接。第一个是铸钢轴承,将倾斜的钢分支和混凝土支撑构件连接起来。为了评估这些混合连接的机械性能和可靠性,在同济大学进行了拟静力试验。这项研究的结果和结论包括:1)由于上部钢柱施加的力矩和接缝附近的柱刚度突然变化,在混凝土柱的顶部观察到了开裂和剥落。建议使用附加的箍筋或外部钢管以增强剪切能力并改善外部混凝土的密闭性。 2)在钢柱底部发生的损坏可能是由于钢的弹性模量和屈服强度在热影响区(HAZ)均降低了约10%,也高于铸钢的预期强度。在对接焊缝附近观察到的损伤与1995年神户地震中的钢结构非常相似。3)根据数值和实验结果,在铸钢轴承中发现了一个潜在的严重损伤断面,但在试验中未损坏。由于铸造材料的强度比热轧钢更不稳定;较大的差异将用于设计强度。因此,铸钢轴承的实际容量很可能被低估,并且铸钢的性能可能不符合原始设计中的预期。 4)此外,基于载荷传递机理的分析和相对于铸钢轴承的弹性旋转刚度的计算,研究了轴承的机械性能和变形能力。还检查了钢柱顶部的位移分量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号