首页> 外文会议>Innovation, practice, safety >EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS
【24h】

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

机译:钢筋混凝土框架与预应力混凝土楼板系统相互作用的试验研究

获取原文

摘要

A three dimensional, approximately half scale experimental test has been carried out to investigate the effect of precast-prestressed floor units on the seismic performance of reinforced concrete moment resisting frames. This paper gives an overview of the experiment and summarizes the results obtained from the test. The paper focuses on the level of strength enhancement and elongation within the plastic hinges. The results show that the presence of prestressed floor units partially restrains elongation of plastic hinges such that elongation in the exterior and interior plastic hinges differs significantly. This increases the strength of the beams more than that specified in the major structural design codes. This is a cause of great concern as this underestimation of beam strength may result in brittle column failure modes in a major earthquake.
机译:进行了一个大约占一半比例的三维实验测试,以研究预制预应力楼板单元对钢筋混凝土抗弯框架的抗震性能的影响。本文概述了实验并总结了从测试中获得的结果。本文着重于塑料铰链内的强度增强和伸长水平。结果表明,预应力地板单元的存在部分抑制了塑料铰链的伸长,因此外部和内部塑料铰链的伸长率明显不同。与主要结构设计规范中指定的强度相比,这增加了梁的强度。由于梁强度的这种低估可能会导致大地震中的脆性柱破坏模式,因此这引起了极大的关注。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有