The reliability of electrical energy networks depends on the quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and might cause high outage and penalty costs. To prevent these destroying events power transformers are e.g. tested on partial discharge (PD) activity before commissioning and currently also during service.The current work deals with the electromagnetic PD detection method, also known as the UHF-Method. The disadvantage of the UHF-Method is still the missing possibility for a calibration or at least a verification of the sensitivity. The so-called Sensitivity Check might show in future a relation between unconventionally measured UHF quantities to the PD apparent charge level in pC. An import aspect is the attenuation of UHF signals within power transformers which is investigated in this paper.
机译:电能网络的可靠性取决于诸如电力变压器之类的电气设备的质量和可用性。绝缘层内部的局部故障可能导致灾难性故障,并可能导致高额的停机和罚款成本。为了防止这些破坏事件,例如使用电力变压器。在调试之前以及当前以及在使用期间对部分放电(PD)活动进行了测试。当前的工作涉及电磁PD检测方法,也称为UHF方法。 UHF方法的缺点是仍然缺少校准或至少验证灵敏度的可能性。所谓的灵敏度检查将来可能会显示非常规测量的UHF量与pC中的PD表观电荷水平之间的关系。一个重要的方面是本文研究了电力变压器中UHF信号的衰减。