首页> 外文会议>GEO-DENVER 2007 >MICROPILE LOAD TESTING AND INSTALLATION MONITORING AT THE CATS VEHICLE MAINTENANCE FACILITY
【24h】

MICROPILE LOAD TESTING AND INSTALLATION MONITORING AT THE CATS VEHICLE MAINTENANCE FACILITY

机译:汽车维修设施中的微负载测试和安装监控

获取原文

摘要

A three-story building was founded on 19.1 cm (7? in) diameter micropiles socketed 4.3 m (14 ft) into the underlying bedrock to meet the strict settlement requirements for a light rail system. A static load testing program consisting of three test piles located across the site was conducted to verify design assumptions concerning micropile axial loading and settlement. In addition, extensive installation monitoring was conducted during micropile installation. The results of the micropile load testing program showed that micropile installation could have a significant influence on pile top load-displacement relationships and pile capacity. Therefore, an extensive production pile monitoring program was conducted to verify proper micropile installation.
机译:在直径19.1厘米(7英寸)的微型桩上建了一座三层楼的建筑,该微型桩插在下面的基岩中4.3 m(14英尺),以满足轻轨系统的严格沉降要求。进行了一个静态载荷测试程序,该程序由遍布整个站点的三个测试桩组成,以验证有关微型桩轴向载荷和沉降的设计假设。此外,在微型桩安装过程中进行了广泛的安装监控。微型桩荷载测试程序的结果表明,微型桩的安装可能对桩顶荷载-位移关系和桩容量产生重大影响。因此,进行了广泛的生产桩监控程序,以验证正确的微型桩安装。