摘要

Six-phase transmission is an optimal solution for increasing the power transmission capability of overhead power transmission lines over existing rights-of-way. This new technology, however, requires a new protection techniques. Therefore, this paper introduces a new technique based on wavelet transform for accurate fault location of six-phase transmission lines. The technique utilizes a wavelet to capture the fault induced high frequency transient currents superimposed on the power frequency currents in a modal domain. The fault location is determined based on the relative arrival times of these high frequency transient signals at the relaying point. The introduced technique is tested and validated through simulation studies. The results show that the technique is accurate in fault location irrespective of the fault type, fault inception angle, and fault resistance. Moreover, it is insensitive to the line terminals and transposition.
机译:六相传输是用于在现有路权上提高架空输电线路的输电能力的最佳解决方案。但是,这项新技术需要一种新的保护技术。因此,本文介绍了一种基于小波变换的六相输电线路故障精确定位技术。该技术利用小波捕获模态域中叠加在工频电流上的故障感应的高频瞬态电流。根据这些高频瞬态信号在中继点的相对到达时间确定故障位置。通过仿真研究对引入的技术进行了测试和验证。结果表明,该技术在故障位置上均是准确的,与故障类型,故障起始角度和故障电阻无关。而且,它对线路端子和换位不敏感。