A California oil refinery reduced process complications and operating costs related tothiosulfate and soluble sulfur generation in its Stretford tail gas units. Removing theautoclave or sulfur melter from the Stretford process eliminated thiosulfate accumulationwithout incurring additional operating or capital costs. The refinery changed operatingmethods and targets in its Claus and Stretford units in an effort to reduce vulnerability toupsets and to increase sulfur plant run length. The refinery attained a record sulfur plant runlength without a functioning air demand analyzer. Only a hydrogen analyzer was operationalon the outlet of the hydrogenator reactor of the tail gas unit.
机译:加利福尼亚一家炼油厂减少了与之相关的过程复杂性和运营成本 在其斯特雷特福德尾气装置中生成硫代硫酸盐和可溶性硫。卸下 斯特雷特福德工艺的高压釜或硫熔炉消除了硫代硫酸盐的积累 不会产生额外的运营或资本成本。炼油厂改变了运营 克劳斯和斯特雷特福德分公司的方法和目标,以减少对 并增加硫磺装置的运行时间。炼油厂的硫磺运行创纪录 长度而没有运行的空气需求分析仪。只有氢气分析仪在运行 在尾气装置的加氢反应器的出口处。