The paper reports the results of a collapse test performed on a 6 m span timber-concrete composite beam with glued re-bar connection. The beam was first ramp loaded to failure, then some push-out tests were performed on specimens cut from the end of the beam in order to fully characterise the connection. During the tests all relevant quantities such as deflections, slips and strains were monitored. The experimental results are compared with those carried out using a FE numerical software and the analytical procedure proposed by Ceccotti according to the Eurocode 5 (EC5). An overall good correspondence was found, as long as realistic properties of the connection such as those obtained through push-out tests are used. Conversely the approximate formulas suggested by the EC5 for evaluating the connection properties are too conservative. Their use may lead to too stiff and strong connections, with possible undesirable brittle failure of the whole composite beam.
机译:这篇论文报告了在一个6 m跨度的木材-混凝土复合梁上用胶粘的钢筋连接进行的倒塌测试的结果。首先对梁进行斜面加载直至破坏,然后对从梁末端切下的样品进行一些推入测试,以充分表征连接。在测试期间,对所有相关量(例如挠度,滑移和应变)进行监控。将实验结果与使用FE数值软件进行的实验结果进行比较,并与Ceccotti根据欧洲规范5(EC5)提出的分析程序进行比较。只要使用了连接的实际属性(例如通过推出测试获得的属性),就可以找到总体良好的对应关系。相反,EC5建议的用于评估连接特性的近似公式过于保守。使用它们可能会导致连接过于僵硬和牢固,从而可能导致整个复合梁发生不希望的脆性破坏。