首页> 外文会议>International Conference on Gas Discharges and Their Applications >DC-PD : A NEW JUDGMENT WAY OF HIGH VOLTAGE PULSE CAPACITORS INSULATION AGING
【24h】

DC-PD : A NEW JUDGMENT WAY OF HIGH VOLTAGE PULSE CAPACITORS INSULATION AGING

机译:DC-PD:高压脉冲电容器绝缘老化的新判断方法

获取原文
获取外文期刊封面目录资料

摘要

It is introduced that the DC-PD measurement of film-paper liquid capacitors is studied by using newly developed DC-PD analyzing system in general electromagnetic screen lab. The research test which include a new balance circuit prove that, the insulation property of the film-paper liquid capacitors is obviously depended on quantity of gas existing in the capacitors; and the DC-PD measurement is affected by the conditions of the environment especially. The insulation property of the film-paper liquid capacitors can be shown by the curve of discharge quantity-discharge time on the basis of a lot of DC-PD testing of film-paper liquid capacitors with the same type.
机译:介绍了在一般电磁屏蔽实验室中,采用最新开发的DC-PD分析系统对薄膜纸质液体电容器的DC-PD测量进行研究的方法。包含一个新的平衡电路的研究测试证明,薄膜纸质液体电容器的绝缘性能显然取决于电容器中存在的气体量。 DC-PD测量尤其受环境条件的影响。薄膜-纸状液体电容器的绝缘性能可以根据许多相同类型的薄膜-纸状液体电容器的DC-PD测试,通过放电量-放电时间曲线来显示。