CT saturation classifications using correlation technique

机译:使用相关技术的CT饱和度分类

获取原文

摘要

This paper presents an algorithm for current transformer (CT) saturation classifications based on correlation technique for bus bar protection. The algorithm calculates the correlation coefficient between the saturated secondary current of the faulted circuit and the summation of the other secondary currents for the un-faulted circuits. The technique classifies the degree of the CT saturation to weak, moderate and severe saturations. The results indicate that the technique is very accurate and useful in selecting the more suitable operating characteristics for differential relays to avoid the false operation.
机译:本文提出了一种基于相关技术的电流互感器饱和度分类的母线保护算法。该算法计算故障电路的饱和次级电流与未故障电路的其他次级电流之和之间的相关系数。该技术将CT饱和度的等级分为弱,中度和重度饱和。结果表明,该技术非常准确,在为差分继电器选择更合适的工作特性以避免误操作方面很有用。