首页> 外文会议>International Symposium on Advanced Optical Manufacturing and Testing Technologies; 20051102-05; Xian(CN) >InGaAs trap detector used as a near-infrared transfer standard for detector calibrations
【24h】

InGaAs trap detector used as a near-infrared transfer standard for detector calibrations

机译:InGaAs陷阱检测器用作检测器校准的近红外传输标准

获取原文

摘要

This paper presents results of investigations of the radiant power spectral responsivity within the near-infrared spectral range. Large-area windowless InGaAs photodiodes of 10mmx10mm are studied in the spectrum ranged from 900 nm to 1600 nm.The InGaAs trap detector used as a transfer standard for power measurements has been characterized and calibrated, obtaining an uncertainty of less than 0.1% at several wavelengths.
机译:本文介绍了在近红外光谱范围内的辐射功率谱响应度的研究结果。在900 nm至1600 nm的光谱范围内研究了10mm x 10mm的大面积无窗InGaAs光电二极管.InGaAs陷阱检测器用作功率测量的传输标准已经过表征和校准,在多个波长下的不确定度均小于0.1% 。