In terms of the characteristic of instantaneous magnetizing inductance reflecting the saturation stage in transformer, an improved method is proposed to distinguish between the magnetizing inrush current and short-circuit fault based on the ratio of average equivalent instantaneous inductances between the non-saturation and the saturation zone, which are divided according to a threshold of differential current. During the inrush, the value of equivalent instantaneous inductance varies severely from small to large as the transformer entering into the saturation and withdrawing from it, so the ratio of average equivalent instantaneous inductances between the non-saturation and the saturation zone is very large in one cycle. However, for the short-circuit fault in transformer, the equivalent instantaneous inductance is very small, and keeps little variation, so the ratio is approximately equal to one. The principle and setting of this method is simple and easy, and its identification time is short. The experimental results verify that the method is correct and effective.
机译:针对反映变压器饱和阶段的瞬时励磁电感的特性,提出了一种基于非饱和与饱和之间的平均等效瞬时电感之比来区分励磁涌流和短路故障的改进方法。区域,根据差分电流的阈值进行划分。在涌流期间,当变压器进入饱和并退出饱和状态时,等效瞬时电感值会从小到大变化很大,因此,非饱和和饱和区之间的平均瞬时电感之比非常大。循环。但是,对于变压器的短路故障,等效瞬时电感非常小,几乎没有变化,因此该比值近似等于1。该方法的原理和设置简单易行,识别时间短。实验结果证明了该方法的正确性和有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号