首页> 外文会议>European Conference on Applied Superconductivity;EUCAS'05 >Measurement of temperature dependent AC losses in HTS bulk by electric and calorimetric methods
【24h】

Measurement of temperature dependent AC losses in HTS bulk by electric and calorimetric methods

机译:通过电和量热法测量高温超导体中与温度相关的交流损耗

获取原文

摘要

HTS bulk can trap higher magnetic field than a permanent magnet and electric motor and actuators are promising applications. The HTS bulks in those electric machines are exposed to AC magnetic field perturbations, which cause AC losses in the bulks. Therefore, it is important to understand the AC loss characteristics. In the previous works, we measured the AC losses by an electric method using the double pick-up coils method. This time, we measured the AC losses by a calorimetric method using a cryo-cooler and heater at different temperature. In this paper, the AC losses measured by the electric and calorimetric methods are compared with each other to investigate the validity of the measurement methods.
机译:与永久磁铁相比,HTS本体可以捕获更高的磁场,电动机和执行器是有前途的应用。这些电机中的HTS散装件受到交流磁场扰动,这会导致散装件中的交流损耗。因此,了解交流损耗特性很重要。在以前的工作中,我们通过电气方法使用双拾波线圈方法测量了交流损耗。这次,我们使用低温冷却器和加热器在不同温度下通过量热法测量了交流损耗。在本文中,将通过电学和量热法测量的交流损耗进行了相互比较,以研究测量方法的有效性。