This paper studies optimum of a negative ion generator with low-ozone emission using corona wire heating technique, and analyzes the effect of the electrode configuration parameter and the electric parameter of negative ion generator on it's performance, such as the negative ion concentration, and the ozone concentration. According to the experimental results, a low-ozone negative ion generator has been designed, and its performance index measures up to the national standard of environment protection.
机译:本文研究了采用电晕丝加热技术的低臭氧排放负离子发生器的优化方法,并分析了负离子发生器的电极构型参数和电参数对其性能的影响,如负离子浓度,负离子浓度,负离子浓度等​​。臭氧浓度。根据实验结果,设计了一种低臭氧负离子发生器,其性能指标达到国家环保标准。