首页> 外文会议>American Society for Composites technical conference >Investigation of the Carbonate Rock Permeability Based on X-Ray Tomography Images 3D Reconstruction and Homogenization of Composites
【24h】

Investigation of the Carbonate Rock Permeability Based on X-Ray Tomography Images 3D Reconstruction and Homogenization of Composites

机译:基于X射线断层扫描图像的碳酸岩渗透性研究3D重建和复合材料均质化

获取原文

摘要

Digital rock physics (DRP) is a nondestructive method to study properties of rocks. Based on this approach, images of rocks are used for determining petrophysical properties such as porosity, permeability and thermal conductivity. In order to study permeability, the real rock microstructure is extracted from binarized rock images. The 3D imaging and segmentation software VCAT (released by V-CAD Program, RIKEN, Japan) has been used to transform medical computed tomography (CT) images to a meshed file that can be imported into commercial software ANSYS for simulating fluid flow and solving Navier-Stokes equations. The rock core samples contained of 10 carbonate pluges with the resolution of 187.5μm. The novelty of this work is to characterize fluid flow properties through rock samples by use of tomography technique and numerical simulations. The full-size plug samples in the medical X-ray CT can be used for imaging, and it is the main advantage of using this method in DRP. However, an important problem with the CT images is their resolution, which may fail to detect those pores which are smaller than the selected resolution. Although in this resolution some pores are not distinguishable, some responses of these pores are mapped on the images based on partial volume effect theory. Based on the descriptions mentioned above, the values of permeability gained from numerical simulations were compared with experimental results of plugs. The computed permeability values had good correlation with the experimental results.
机译:数字岩石物理(DRP)是一种学习岩石性质的无损方法。基于这种方法,岩石的图像用于确定岩石物理性质,例如孔隙率,渗透性和导热率。为了研究渗透性,真正的岩石微观结构从二值化岩图像中提取。 3D成像和分割软件VCAT(由V-CAD程序发布,RIKEN,日本)已被用于将医疗计算机断层扫描(CT)图像转换为可用于模拟流体流量和解决NAVIER的商业软件ANSYS的网状文件 - 方程式。岩石核心样品含有10个碳酸盐塞,分辨率为187.5μm。这项工作的新颖性是通过使用断层扫描技术和数值模拟来表征通过岩石样本的流体流动性能。医用X射线CT中的全尺寸插头样品可用于成像,并且它是在DRP中使用该方法的主要优点。然而,CT图像的重要问题是它们的分辨率,其可能无法检测到小于所选择的分辨率的那些孔。虽然在该分辨率中,一些孔不可区分,但是基于部分体积效应理论映射这些孔的一些反应。基于上述描述,将以数值模拟的渗透率与塞子的实验结果进行比较。计算的渗透率值与实验结果具有良好的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号