A non-radioactive method was optimised and approved for measuring the mixing efficiency of a chemical mixture,i.e. the evenness of chemical distribution in a pulp sample, using lithium chloride as tracer.With a laboratory kneader, mixing efficiencies in the range of 91- 96% were obtained. Further, it was shown that alower mixing efficiency leads to a reduced bleaching effect, which demonstrated that the method as described is asuitable measure for assessing the mixing efficiency.The mixing efficiency of industrial-scale HC mixers was between 86 and 94% and thus, well within the range of thelaboratory mixer.Calculations demonstrated that the peroxide consumption in a HC bleach plant is 5% higher at a mixing efficiency of80%, compared with ideal mixing.The measuring method described above allows us to measure the mixing efficiency of almost every available mixerand to quantify possible savings in chemicals achieved by improving the mixing efficiency.
机译:优化并批准了一种非放射性方法,用于测量化学混合物的混合效率, 即使用氯化锂作为示踪剂在纸浆样品中化学分布的均匀性。 使用实验室捏合机,可获得91-96%的混合效率。此外,还表明 较低的混合效率导致降低的漂白效果,这表明所描述的方法是一种 评估混合效率的合适措施。 工业级HC混合器的混合效率在86%至94%之间,因此,在 实验室搅拌机。 计算表明,在HC漂白厂中,混合效率为5%时,过氧化物消耗量增加了5%。 与理想混合相比为80%。 上述测量方法使我们能够测量几乎所有可用搅拌机的搅拌效率 并量化通过提高混合效率可节省的化学药品。