首页> 外文会议>International conference on nuclear engineering;ICONE-8 >Development of oecd bwr turbine trip transient benchmark for validation of coupled three-dimensional neutronics/thermalhydraulic system codes
【24h】

Development of oecd bwr turbine trip transient benchmark for validation of coupled three-dimensional neutronics/thermalhydraulic system codes

机译:开发OECD BWR涡轮跳闸瞬态基准以验证三维中子/热工液压系统代码耦合

获取原文

摘要

Turbine trip (TT) in a boiling water reactor (BWR) is a sudden closure of the turbine stop valve (TSV). The pressure oscillation generated in the main steam piping propagates with relatively little attenuation into the reactor core. The core pressure induced oscillations result in dramatic changes in the core void distribution and fluid flow. THe magnitude of the neutron flux transient taking place in the BWR core is strongly affected by the initial rate of pressure rise cause by the pressure oscillation and has a strong spatial variation.
机译:沸水反应堆(BWR)中的涡轮跳闸(TT)是涡轮截止阀(TSV)的突然关闭。在主蒸汽管道中产生的压力振荡以相对较小的衰减传播到反应堆堆芯中。岩心压力引起的振荡导致岩心空隙分布和流体流量发生剧烈变化。在BWR堆芯中发生的中子通量瞬变的大小受压力振荡引起的初始压力上升速率的强烈影响,并且具有很大的空间变化。