摘要

One key factor for optimum performance of SNCR-based deNOx systems is that the ammonia is introduced in a correct temperature window around 1220 K. Traditional temperature measurement principles using stand alone thermocouples or in a combination with gas suction devices are known to be effected by several hundred degrees by the surrounding environment. This paper demonstrates the use of CARS as a gas temperature diagnostic tool at theprosition of the ammonia injection in a full scale 80 MW PF boiler.
机译:基于SNCR的脱硝系统最佳性能的一个关键因素是将氨引入到大约1220 K的正确温度范围内。使用独立的热电偶或与吸气装置结合使用的传统温度测量原理受以下因素影响:周围环境百度。本文演示了在大规模80 MW PF锅炉氨注入过程中使用CARS作为气体温度诊断工具的情况。