首页> 外文会议>ACEEE summer study on energy efficiency in buildings >Roof Heating and Cooling Loads in Various Climates for the Range of Solar Reflectances and Infrared Emittances Observed for Weathered Coatings
【24h】

Roof Heating and Cooling Loads in Various Climates for the Range of Solar Reflectances and Infrared Emittances Observed for Weathered Coatings

机译:风化涂层的各种太阳反射率和红外发射率范围内,各种气候下的屋顶加热和冷却负荷

获取原文

摘要

Twenty-foure low-slope roof coating systems and four uncoated specimens have been in place since June 1997, exposed to the Knoxyville, Tennessee climate. Local weather conditions, temperatures from top to bottom of each 2 ft x 2 ft (0.61 m x 0.61 m) test section adn heat flux through the wood fiberboard roof insulation for each test section have been recorded continuously. Periodically, each surface's reflectance over the solar spectrum and emittance in the infrared have been measured in-situ. These data permit direct validation of a computer program for onedimensional, transient analysis of roof thermal performance.
机译:自1997年6月以来,已经有24个低坡度屋顶涂层系统和四个未涂层的标本,它们暴露于田纳西州Knoxyville的气候中。连续记录当地天气状况,每个2 ft x 2 ft(0.61 m x 0.61 m)测试段的上下温度以及每个测试段通过木纤维板屋顶隔热层的热通量。定期测量每个表面在太阳光谱上的反射率和在红外线中的发射率。这些数据可以直接验证用于屋顶热性能的一维瞬态分析的计算机程序。