首页> 外文会议>ASME pressure vessels and piping conference >Analysis of possibility of pressure tube cold pressurisation during ECCS injection for a small break loca
【24h】

Analysis of possibility of pressure tube cold pressurisation during ECCS injection for a small break loca

机译:对ECCS注入过程中小断裂部位压力管冷加压的可能性进行分析

获取原文
获取外文期刊封面目录资料

摘要

ECCS is designed to keep the reactor fuel temperatures within safe limits. The paper describes an additional criterion for Indian Pressurised Heavy Water Reactors (IPHWRs) evolving from the need to avoid a small break Loss of Cooling Accident (LOCA) developinginto a more severe accident. During a small break loss of coolant Accident (LOCA) in PHWRs, the hydro-accumulators ride on the system and inject emergency coolant. The Atmospheric Steam Discharge Valves (ASDVs) open and cool the systme due to energy discharge. In addition the pressure control systme tends to maintain the pressure Depending on the systme deisgn, ithis could lead to cold pressurisation fo the system. This paper examines this issue.
机译:ECCS旨在将反应堆燃料温度保持在安全范围内。本文描述了印度加压重水反应堆(IPHWR)的另一条标准,该标准从避免小规模的冷却事故损失(LOCA)发展为更严重的事故演变而来。在PHWR中的冷却液意外事故(LOCA)损失很小的情况下,蓄能器会骑在系统上并注入应急冷却液。大气蒸汽排放阀(ASDV)由于能量释放而打开并冷却系统。另外,压力控制系统趋向于保持压力。根据系统设计,这可能导致系统的冷压。本文研究了这个问题。