For a secondary mass damper such as tuned liquid damper (TLD) or tuned liquid column damper (TLCD), whose moving mass is liquid, it is impossible to pre-fabricate the damper in a factory for the identification of dynamic properties. Also, it is not easy to pre-fabricate a concrete tuned mass damper (TMD) in a factory whose moving mass is made of concrete. In this paper, an identification method of dynamic properties of secondary mass dampers based on the forced vibration test is presented. Decoupled equations of motion are derived from a coupled equation of motion of building and damper. The decoupled equations of motion are then applied to the system identification using the response of the damper as an input and the response of the building as an output. The proposed method is applied to numerical examples and an actual TMD and TLCD installed in buildings.
机译:对于诸如调谐液体阻尼器(TLD)或调谐液柱阻尼器(TLCD)的二级质量阻尼器(TLCD),其移动质量是液体,不可能在工厂中预先制造阻尼器以识别动态特性。此外,在移动质量由混凝土制成的工厂中,不容易预先制造混凝土调谐质量阻尼器(TMD)。本文介绍了基于强制振动试验的二次质量阻尼器的动态特性识别方法。去耦的运动方程源自建筑物和阻尼器的耦合方程。然后使用阻尼器作为输入的输入和响应作为输出的响应,将解耦的运动方程应用于系统标识。该方法应用于数值示例和安装在建筑物中的实际TMD和TLCD。