This paper presents a series of tests on strengthened ferritic stainless steel tubular members using externally bonded high modulus Carbon Fibre-Reinforced Polymer (CFRP) plate. The CFRP plate strengthening is only applied to a small localize region subjected to concentrated load. The tubular members of square and rectangular hollowsections subjected toweb cripplingwere tested. Theweb crippling testswere conducted under two loading conditions of End-Two-Flange (ETF) and End-One-Flange (EOF). The tests were performed on five different sizes of tubular sections.Tensile coupon testswere conducted to determine the material properties of the ferritic stainless steel specimens. Most of the strengthened specimens were failed by debonding of CFRP plate from the ferritic stainless steel tubes. Two different failure modes were observed in the tests of the strengthened specimens, namely the adhesion failure as well as the combination of adhesion and cohesion failure. The failure loads, failure modes and the load-web deformation behaviour of the ferritic stainless steel sections are also presented in this paper.
机译:本文介绍了一系列关于强化铁素体不锈钢管状构件的试验,使用外粘合的高模量碳纤维增强聚合物(CFRP)板。 CFRP板强化仅应用于经过浓载荷的小定位区域。方形的管状构件和矩形空洞的管状构件受到ToweB Cripplingwere的测试。 TheWeb中继试验在两端 - 法兰(ETF)和端部法兰(EOF)的两个装载条件下进行。测试是对五种不同尺寸的管状切片进行的测试。进行的抗敏优惠券测试以确定铁素体不锈钢样品的材料特性。大多数增强的标本通过从铁素体不锈钢管中剥离CFRP板而失败。在增强的标本的测试中观察到两种不同的故障模式,即粘附衰竭以及粘合性和粘合性的组合。本文还介绍了铁素体不锈钢部分的故障载荷,故障模式和负载网变形行为。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号