Using the ultrasonic/Fenton oxidation to remove 2-chlorophenol from wastewater is presented this 354paper. The combining ultrasonic and Fenton treatment enhances the decomposition efficiency of 2-chlorophennol and reduced the reaction time. In previous studies, the optimal conditions for carrying out the proposed ultrasonic/ Fenton process are: pH maintained at 3, ionic strength of the solution adjusted at 0.1 N, ultrasonic amplitude maintained at 120 mm, and the reaction temperature controlled at 25 deg C. In this study, the influent of Fenton reagent concentration and ratios of Fe~2+ to H_2O_2 on the removal efficiency of 2-chlororphenol is investigated. Laboratory results indicate that the percentage of 2-chlorophenol decomposition increases for higher concentrations of Fenton reagent applied. If the concentration of H_2O_2 exceeds 50 mg/L, more than 100
机译:354篇论文介绍了使用超声波/ Fenton氧化法从废水中去除2-氯苯酚的方法。超声与Fenton处理相结合提高了2-氯苯酚的分解效率并缩短了反应时间。在以前的研究中,进行拟议的超声/芬顿工艺的最佳条件是:pH保持在3,溶液的离子强度调节在0.1 N,超声振幅保持在120 mm,反应温度控制在25摄氏度。本文研究了Fenton试剂浓度和Fe〜2 +与H_2O_2比对2-氯苯酚去除率的影响。实验室结果表明,使用更高浓度的Fenton试剂,2-氯苯酚分解的百分比会增加。如果H_2O_2的浓度超过50 mg / L,则超过100