Natural gas distributed in the Netherlands contains very little sulphur.the sulphur content is currently below 10 milligrams per cubic metre.Most o fthe sulphur which is present comes from the trtrahydrothiophene added to the gas as odorant.Prior to 1994,however,a sulphur content of up to 150 milligrams per cubic metre of naturla gas was permitted.the effect of such a high sulphur content on the corrosion of materials and different ytpes of joint in condensing appliances was unknown.to investigate this effect,tests were carried out using naturla gas with the high sulphur content as well as with today's low sulphur content.For this purpose,a test rig was built enabling the performnce of different materials to be compared under simulated practical conditions.The results obtained over a test period of twelve months were extrapolated over the desing life of fifteen years.
机译:荷兰分布的天然气中的硫很少。目前的硫含量低于每立方米10毫克。存在的大部分硫来自四氢噻吩作为增香剂添加到气体中。然而,1994年之前,硫含量低最高允许每立方米天然气150毫克。如此高的硫含量对冷凝器中材料腐蚀和接头不同类型的腐蚀的影响尚不清楚。为了研究这种影响,使用天然气进行了测试为此,建立了一个试验台,可以在模拟的实际条件下比较不同材料的性能。设计寿命为十五年。