首页> 外文会议>International joint power generation conference >Operation of turbines with fire resistant fluids, including the lubricating system
【24h】

Operation of turbines with fire resistant fluids, including the lubricating system

机译:使用耐火流体的涡轮机(包括润滑系统)运行

获取原文

摘要

According to an internal VGB report, there have been 83 publicized cases worldide involving substantial fire damage to turbine generator sets between 1971 and 1997 [1]. Clearly, we must assume that the data in the report does not cover every incident that occurred during this period. These incidents involved ten deaths and a large number of injuries. Property damage in one case alone ammounted to US-dollar 41 million, while some incidents resulted in shutdowns lasting up to one year (Figure 1).
机译:根据VGB的内部报告,在1971年至1997年之间,全世界共有83例公开案例涉及涡轮发电机组的重大火灾[1]。显然,我们必须假设报告中的数据并不涵盖此期间发生的所有事件。这些事件涉及十人死亡和大量伤害。仅在一个案例中,财产损失就高达4100万美元,而一些事件导致停工长达一年(图1)。