In order to make benchmark validation of the existing evaluated nuclear data for fusion related material, neutron leakage spectra from spherical piles were measured with a time-of-flight technique using the intense 14 MeV neutron source, OKTAVIAN in the energy range from 0.1 to 15 MeV. The neutron energy spectra were obtained as the absolute value normalized per the source netron. The measured spectra were compared with those by theoretical calculation using a Monte arlo neutron transport code, MCNP with several libraries processed from the evalauted nuclear data files. comparison has been made with the spectrum shape, the C/E values of neutron numbers integrated in 4 energy regions and the calculated spectra unfolded by the number of collisions, especially those after a single collision.
机译:为了对融合材料的现有评估核数据进行基准验证,使用飞行时间技术,使用强14 MeV中子源OKTAVIAN,在0.1至15的能量范围内,通过飞行时间技术测量了球形堆的中子泄漏谱。 MeV。获得的中子能谱是按源内控管归一化的绝对值。将测得的光谱与使用蒙特阿罗中子输运代码MCNP进行的理论计算进行比较,并具有从隐匿的核数据文件中处理的几个库。比较了光谱形状,在四个能量区域中积分的中子数的C / E值以及通过碰撞次数(尤其是一次碰撞后的碰撞次数)展开的计算光谱。