Seismic-caused postulated break of hig energy piping in nuclear power plants is an important safety topic. For Class 1,2, and 3 piping, the U.S Nuclear Regulatory Commission (NRC) Standard Review Plan (SRP) Section 3.6.2 provides acceptance criteria on the design basis for high energy piping break analysis. This paper presents a case study with the approaches and results of high energy piping break analyses, which are on the basis of continued safe operation using a nonlinear response spectrum method for a typcial existing non-seismic-designed ANSI B31.1 non-safety main steam piping system.
机译:地震导致的核电厂高能能源管道的假定断裂是重要的安全主题。对于1,2级和3级管道,美国核监管委员会(NRC)标准审查计划(SRP)第3.6.2节提供了基于设计的高能管道破裂分析验收标准。本文针对高能管道断裂分析的方法和结果进行了案例研究,这些方法和结果基于使用非线性响应谱法对典型的现有非地震设计的ANSI B31.1非安全主体进行持续安全操作的基础上蒸汽管道系统。