Experimental investigation on critical heat flux of flow boiling in a vertical uniformly heated annular channel has been performed under rolling and without rolling conditions. The test loop employed in the experiments was fixed on a rolling test facility so that different rolling angles and periods can be achieved. The range of the experiment parameters is as follows: pressure P=0.02MPa, mass velocity G=400 approx 2000kg/m~2s, inlet subcooling temperature DELTAT_sub=5 approx 55 deg C, limit rolling angle theta_m=5 deg, 10 deg, 15 deg, rolling period tau=5s, 7.5s, 10s.
机译:在轧制和无轧制条件下,对垂直均匀加热的环形通道中的沸腾流的临界热通量进行了实验研究。实验中使用的测试回路固定在滚动测试设备上,因此可以实现不同的滚动角度和周期。实验参数的范围如下:压力P = 0.02MPa,质量G = 400约2000kg / m〜2s,入口过冷温度DELTAT_sub = 5约55摄氏度,极限滚动角theta_m = 5摄氏度,10摄氏度, 15度,滚动周期tau = 5s,7.5s,10s。