首页> 外文会议>International technical conference on coal utilization fuel systems >Test Results from the Co-firing of Coal Water Slurry Fuel in a 32 Megawatt Pulverized Coal Boiler
【24h】

Test Results from the Co-firing of Coal Water Slurry Fuel in a 32 Megawatt Pulverized Coal Boiler

机译:在32兆瓦粉煤锅炉中将水煤浆燃料共烧的测试结果

获取原文

摘要

1. CWS was successfully co-fired in a 32 MWe utility boilerwithout disruption of boiler performance.2. Low solids CWS co—firing results in a reduction in NOx by15 to 20% under the conditions tested at the Seward Station.3. Emission levels of CO, SO_2 and particulates, as indicated byopacity measurements, were essentially the same as with normal pc firing levels but CO levels were highly variable.4. CWS handling and feeding systems installed at the SewardPlant performed within design parameters.5. CWS firing was successfully integrated into the boilercontrol system.6. Seward Station plant operators accepted the CWS firing asroutine by the end of the test program.
机译:1. CWS在一台32 MWe的电站锅炉中成功地共烧 不会影响锅炉性能。 2.低固含量的CWS共燃可降低NOx排放量 在Seward站测试的条件下为15%到20%。 3. CO,SO_2和颗粒物的排放水平,如 浊度测量值与正常pc点火水平基本相同,但一氧化碳水平变化很大。 4.在苏厄德(Seward)安装的CWS处理和进料系统 在设计参数范围内执行工厂。 5. CWS燃烧成功集成到锅炉中 控制系统。 6.苏厄德站的工厂运营商接受了CWS的解雇 例行测试程序结束时。