首页> 外文会议>International conference on structural mechanics in reactor technology;SMiRT 20 >Experimental Study on Seismic Reduction Effectiveness of Main Control Room in N.P.P using 3-Directional Isolation System
【24h】

Experimental Study on Seismic Reduction Effectiveness of Main Control Room in N.P.P using 3-Directional Isolation System

机译:三向隔离系统对N.P.P主控室减震效果的实验研究

获取原文

摘要

The main control room of a nuclear power plant operates many important NPP facilities such as NSSS, so it is highly recommended to secure seismic safety of main control room during and after earthquakes. A number of isolation systems installed between equipment and foundation have been widely studied. In this study, 3-Directional isolation systems was used which are consist of a FPS(Friction Pendulum System), an air spring and a viscous damper. A FPS is resistant to horizontal motion and an air spring is resistant to vertical motion and a viscous damper is resistant to rocking motion and excessive displacement. In this study, two types of main control floor systems were taken into account and a number of shaking table tests with or without isolation system were conducted to evaluate 3D isolation reduction effectiveness.
机译:核电厂的主控制室运行着许多重要的NPP设施,例如NSSS,因此强烈建议在地震期间和之后确保主控制室的地震安全。已经广泛研究了安装在设备和基础之间的许多隔离系统。在这项研究中,使用了三向隔离系统,该系统由FPS(摩擦摆系统),空气弹簧和粘性阻尼器组成。 FPS可以抵抗水平运动,而空气弹簧则可以抵抗垂直运动,而粘性阻尼器则可以抵抗摇摆运动和过度位移。在这项研究中,考虑了两种类型的主控制地板系统,并进行了带有或不带有隔离系统的多个振动台测试,以评估3D隔离减少效果。