摘要

A Round Robin test for the sound absorption using the reverberation chamber method is performed. From the measurements it can be concluded that: the measured sound absorption of a high absorbing material is larger than 1,0, both for the lower frequency range, where this can be attributed to the edge effect, as for the higher frequencies the Reproducibility of the absorption measurement is rather poor a limited number of 'outliers' is responsible for this Reproducibility
机译:进行了使用混响室方法进行吸声的Round Robin测试。从测量结果可以得出以下结论:在较低的频率范围内,高吸声材料的测得的吸声率均大于1,0,这可归因于边缘效应,而在较高的频率下,吸收度测量结果很差,造成这种再现性的原因是数量有限的“离群值”