The Nanoconverter [1] is used in two beam lines of the Swiss Light Source synchrotron (SLS) at the Paul Scherrer Institut (PSI). One is TOMCAT (Tomographic Microscopy Radiology Experiment, M. Stampanoni), the other cSXAS (Coherent Small Angle X- ray Scattering, F. Pfeiffer). There, the Nanoconverter is used to move gratings with pitches of a few microns. For some experiments the grating has to be moved during x- ray exposure with an accuracy of 20 nanometers over a typical range of 30 microns. One year ago, S. Henein presented the Nanoconverter at the Euspen International Conference in Bremen. In his abstract, it was said, that a "large constant reduction factor ... typically between 20 and 1000" can be achieved. Mr. Henein also mentioned in his abstract, that the design has a fixed reduction ratio of 100. In the meantime 2 of the 4 built Nanoconverter are in use in the experiments very satisfactory. The others were used to verify the reduction factor and the absolute movement of the output, based on the input movement of the stepper motor.
机译:纳米转换器[1]用于Paul Scherrer研究所(PSI)的瑞士光源同步加速器(SLS)的两条光束线中。一种是TOMCAT(断层显微照相放射学实验,M。Stampanoni),另一种是cSXAS(相干小角X射线散射,F。Pfeiffer)。在那里,纳米转换器用于移动间距为几微米的光栅。对于某些实验,必须在X射线曝光期间以20纳米的精度在30微米的典型范围内移动光栅。一年前,S。Henein在不来梅举行的Euspen国际会议上介绍了纳米转换器。在他的摘要中,有人说,可以实现“较大的常数减小因子,通常在20到1000之间”。 Henein先生在摘要中还提到,该设计的固定缩小比例为100。同时,在实验中使用的4台纳米转换器中有2台非常满意。其他的则用于根据步进电机的输入运动来验证减速系数和输出的绝对运动。