首页> 外文会议>Workshop on severe accident research, Japan;SARJ-99 >Measurements of Radiation Dose Level Around 3W1 Beamline of Beijing Electron-Positron Collider
【24h】

Measurements of Radiation Dose Level Around 3W1 Beamline of Beijing Electron-Positron Collider

机译:北京电子-正电子对撞机3W1光束线周围辐射剂量水平的测量

获取原文

摘要

This paper describes the possible radiation sources and their characteristics around 3W1 beamline of Beijing Electron-Positron Collider (BEPC). A homemade monitoring system is used to measure the dose level around 3W1 beamline. The obtained results show that the radiation field depends on the BEPC operation status. During the normal storage operation, the radiation field is a slowly changing field close to a constant. The dose level is proportional to the beram intensity. However when electrons are injected into the storage ring, the radiation field becomes a fast changing field with a very high dose level. Furthermore our results indicate that accidentally the beam loss occurred near to 3W1 beamline, which led to the fast increase of dose level.
机译:本文描述了北京电子正对撞机(BEPC)3W1光束周围可能的辐射源及其特性。自制的监视系统用于测量3W1光束线附近的剂量水平。获得的结果表明,辐射场取决于BEPC的运行状态。在正常存储操作期间,辐射场是接近常数的缓慢变化的场。剂量水平与贝拉姆强度成正比。但是,当电子注入存储环时,辐射场变成剂量非常高的快速变化的场。此外,我们的结果表明,意外的光束损失发生在3W1光束线附近,这导致剂量水平快速增加。