首页> 外文会议>IEEE Industry Applications Society annual meeting >Ozone production in electrostatic air cleaners with contaminated electrodes
【24h】

Ozone production in electrostatic air cleaners with contaminated electrodes

机译:耐污水清洁器中的臭氧生产污染电极

获取原文

摘要

Wind tunnel tests were conducted to assess independently the contributions of contaminated wires and plates to ozone production in positive-polarity, wire-plate air cleaners. After one week of operation in filtered air containing Arizona road dust, ozone concentration in a laboratory air cleaner increased by 460%. In this case, there was slight contamination on the discharge wires, but the ozone increase is attributed exclusively to back corona on the collection plates. Oxidized discharge wires were believed to contribute to an order of magnitude increase in ozone concentration in a commercial air cleaner operated in room air for seven weeks. It was found that wire contamination alone can increase ozone generation. An insulating tape adhesive applied to a 0.254 mm-diameter stainless steel wire caused a tenfold increase in ozone concentration. Scanning electron microscopy and energy dispersive spectroscopy were used to characterize contaminate morphology and elemental composition.
机译:进行风洞测试以独立评估污染的电线和板在正极性,线材空气清洁器中产生臭氧产生的贡献。在含有亚利桑那州的过滤空气的过滤空气的一周后,实验室空气清洁器中的臭氧浓度增加了460%。在这种情况下,放电线上有轻微的污染,但臭氧增加仅归因于收集板上的电晕。据信氧化放电线被贡献到在室内空气中在室内空气中运行七周的商用空气净化器中臭氧浓度增加的数量级。发现单独的电线污染可以增加臭氧产生。施加到0.254毫米不锈钢线的绝缘带粘合剂导致臭氧浓度的十倍增加。扫描电子显微镜和能量色散光谱用于表征污染物形态和元素组成。