首页> 外文会议>IEEE International Symposium on Electrical Insulation >Electrical aging of inverter-fed wire-wound induction motors: from quality control to end of life
【24h】

Electrical aging of inverter-fed wire-wound induction motors: from quality control to end of life

机译:逆变器送丝缠绕电动机的电老化:从质量控制到生命结束

获取原文

摘要

In this paper, the IEC 60034-18-41 technical standard procedures for assessing the quality of Type I (random wound) motors through (offline) partial discharge testing are briefly summarized first. After, offline and online measurements performed on one motor, able to pass the tests but failed soon after energization through a PWM inverter, will be compared. The analysis will highlight the pros and cons of the standard.
机译:本文首先概述了用于评估I(随机伤口)电机质量的IEC 60034-18-41技术标准程序通过(离线)局部放电测试简要概述。在一个电机上执行的离线和在线测量,能够通过测试,但通过PWM逆变器通电很快发生故障,将进行比较。分析将突出标准的优缺点。