In this paper, in order to develop the diagnostic technique, we deteriorated the low-voltage cables accelerately under some thermal conditions and investigated the correlations related to elongation which could be considered as a value ofdegradation degree.As the experimental results, we found that the diagnostic technique of the equotip hardness method has its merits of nondestruction, small error and simplicity. Moreover we investigated the correlation between the equotip hardness and the elongation atbreak of PVC sheaths of several low-voltage cables, and obtained the master curve between equotip hardness and elongation. And then we developed the diagnostic apparatus based on the equotip hardness method.
机译:在本文中,为了开发诊断技术,我们在一些热条件下加速了低压电缆,并研究了与伸长率相关的相关性,这可以被认为是横向程度的值。我们发现了实验结果,我们发现了单位硬度方法的诊断技术具有非信贷,误差和简单的优点。此外,我们调查了几个低压电缆的平衡硬度和PVC护套的伸长率与伸长率之间的相关性,并获得了轮孔硬度和伸长率之间的主曲线。然后我们开发了基于轮廓硬度法的诊断装置。