Isothermal Differential Calorimetry as a means to measure insulation aging rate down to the operating temperatures

机译:等温差示量热法可测量低至工作温度下的绝缘老化率

获取原文

摘要

1. Isothermal Differential Calorimetry makes it possible to measure aging reaction rate down to service temperatures. 2. The reactions taking place in the aging processes can be separated by using appropriate gas mixtures for test atmospheres. 3. Reaction rate curves do not give an easy solution to the extrapolation problem of the life test results, because the reaction rate curves may be atmosphere dependent, pre-aging time dependent and pre-aging temperature dependent. 4. For further investigation of the extrapolation problem, conventional life tests should be conducted in the same controlled atmospheres as the reaction rate measurements. The effects of the different aging reactions on the useful lives of insulating materials could then be estimated.
机译:1.等温差示量热法可以测量直至使用温度的老化反应速率。 2.在老化过程中发生的反应可以通过使用用于测试气氛的适当气体混合物来分离。 3.反应速率曲线不能轻易解决寿命测试结果的外推问题,因为反应速率曲线可能与气氛有关,与时效时间有关和与温度有关。 4.为了进一步研究外推问题,应在与反应速率测量相同的受控气氛下进行常规寿命测试。然后可以估算出不同的老化反应对绝缘材料使用寿命的影响。