In this paper, a low budget calorimetric chamber for the measurement of power losses and the determination of efficiency in the range of Ploss = 2 - 100 W is proposed. The overall working principle has been based on the work of [1], taking this design from a 25 mW-level to a 4000-fold measuring range. The expected measurement error of this system is in the range of ±0.7% ≤ etotal ≤ ±1.8% depending on the power loss of the underlying device under test.
机译:在本文中,提出了一种用于测量功率损耗的低预算量热室和褶皱+ 2-100W范围内的效率的确定。 整体工作原理一直基于[1]的工作,将这种设计从25兆瓦的水平到4000倍的测量范围。 该系统的预期测量误差在±0.7%≤entotal≤±1.8%的范围内,具体取决于底层设备的功率损耗。