Concerning the character of condensing dehumidification,the analytical mode about the cascade use of cooling energy in blast furnace blower system has been built through material balance method and heat balance method.According to the analytical mode,the actual data,which comes from certain steel works,have been analyzed.Here are the calculating results: Condensing water in 10℃ are produced within 22.56 tons per hour in one day.Through the water treatment of removing copper ion,the condensate water could be used in the condenser of one refrigerator,and lower the cooling water in 1.Meanwhile,it results in enhancing heat transferring and increases the cooling energy of refrigerating system in 352 kW.
机译:针对冷凝除湿的特点,通过物料平​​衡法和热平衡法建立了高炉鼓风机系统冷却能级联利用的分析模式。根据分析模式,实际数据来自某钢厂计算结果如下:一天内每小时产生22.56吨每小时10℃的冷凝水。通过去除铜离子的水处理,冷凝水可用于一台冰箱的冷凝器中,并且降低1中的冷却水,同时,提高了传热效率,增加了352 kW制冷系统的冷却能量。

著录项

  • 来源
    《》|2013年|1232-1235|共4页
  • 会议地点 Chengdu(CN)
  • 作者单位

    College of Energy and Power Engineering, University of Shanghai for Science and Technology,Shanghai, China;

    College of Energy and Power Engineering, University of Shanghai for Science and Technology,Shanghai, China;

    College of Energy and Power Engineering, University of Shanghai for Science and Technology,Shanghai, China;

    College of Energy and Power Engineering, University of Shanghai for Science and Technology,Shanghai, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 TB346;
  • 关键词

    cooling dehumidification; condensate water; circulating cooling water;