首页> 外文会议> >Upgrading the General Atomics Radio-Frequency Sources for Higher Power
【24h】

Upgrading the General Atomics Radio-Frequency Sources for Higher Power

机译:升级通用原子无线电频率源以提高功率

获取原文

摘要

Several years ago the Princeton Plasma Physics Laboratory (PPPL), Oak Ridge National Laboratory (ORNL) and General Atomics (G.A.) formed a collaboration to return the three G.A. radio-frequency (RF) sources to service, and to upgrade the two higher frequency range RF sources to have larger 2.5 megawatt power tubes for greater output power. To date, the 60 Mhz source is routinely operated into G.A.''s Doublet III D (DIIID) experiment at a power level up to 1 MW. The power tube upgrade for one of the higher frequency sources has been completed and has been tested to 1.4MW into a test load and 750kW into plasmas. Preparations for the tube upgrade for the other higher frequency source is now underway.
机译:几年前,普林斯顿等离子体物理实验室(PPPL),橡树岭国家实验室(ORNL)和通用原子(G.A.)组成了一项合作,以归还这三个G.A。射频(RF)源进行服务,并升级两个更高频率范围的RF源,使其具有更大的2.5兆瓦功率管,从而获得更大的输出功率。迄今为止,60 Mhz光源通常在功率高达1 MW的G.A Doublet III D(DIIID)实验中进行操作。一种高频源的功率管升级已经完成,并已测试到测试负载为1.4MW,等离子为750kW。正在为其他更高频率的源进行电子管升级的准备工作。