This paper presents an on-line correction method of current measurement errors for a pure-integration-based flux estimation down to 1-Hz stator frequency. An observer-based approach is taken as one possible solution of eliminating the dc offset and the negative sequence component of unbalanced gains in the synchronous coordinate. At the same time, the positive sequence component estimation is performed by creating an error signal between a motor model reference and an estimated q-axis rotor flux established by a permanent magnet (PM) in the synchronous coordinate. The compensator utilizes a PI controller that controls the error signal to zero. The proposed technique further contains a residual error compensator to completely eliminate miscellaneous disturbances in the estimated flux. The developed algorithm has been implemented on a 1.1-kW permanent magnet synchronous motor (PMSM) drive to confirm the effectiveness of the proposed scheme.
机译:本文提出了一种电流测量误差的在线校正方法,可用于低至1Hz定子频率的基于纯积分的磁通估算。基于观察者的方法是消除同步坐标中直流偏移和不平衡增益的负序分量的一种可能解决方案。同时,通过在电动机模型参考与永磁坐标(PM)在同步坐标中建立的估计q轴转子磁通之间创建误差信号来执行正序分量估计。补偿器利用PI控制器将误差信号控制为零。所提出的技术还包括残余误差补偿器,以完全消除估计通量中的其他干扰。所开发的算法已在1.1 kW永磁同步电动机(PMSM)驱动器上实施,以确认所提出方案的有效性。

著录项

  • 来源
    《》|2007年|845-850|共6页
  • 会议地点
  • 作者

    Cho; Kyung-Rae; Seok; Jul-Ki;

  • 作者单位
  • 会议组织
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号