首页> 外文会议> >Noninvasive ultrasonic transdermal insulin delivery in rabbits using the light weight cymbal array
【24h】

Noninvasive ultrasonic transdermal insulin delivery in rabbits using the light weight cymbal array

机译:轻型c阵列在兔中进行无创超声透皮胰岛素递送

获取原文

摘要

The purpose of this study was to demonstrate US transdermal delivery of insulin in vivo using rabbits with a novel, low profile two-by-two US array based on the cymbal transducer. As a practical device, the cymbal array (f=20 kHz) was 37/spl times/37/spl times/7 mm/sup 3/ in size and weighed less than 22g. With a similar intensity (I/sub sptp/=100 mW/cm/sup 2/, 20% duty cycle), our goal was to determine if the same effect could be achieved with rabbits. Fourteen New Zealand White rabbit (2.7-3.4 kg) experiments were performed in three groups: two controls and one US with insulin exposure. The first group (control 1) had insulin placed in the reservoir with no US while the second group (control 2) had saline in the reservoir with US operating at I/sub sptp/=100 mW/cm/sup 2/ for 60 minutes. The third group (US-Insulin) was subjected to insulin with US exposure for 60 minutes (I/sub sptp/=100 mW/cm/sup 2/). At the commencement of the experiment, 0.3 mL of blood was collected from the ear vein to determine the blood glucose level (mg/dL) using a blood glucose monitoring system. The insulin reservoir was removed with the array after the US was turned off at 60 minutes exposure. For both control 1 and 2, the blood glucose level showed an increase at 15 and 30 minutes and remained at approximately +50 mg/dL. For the US-Insulin group, the glucose level was found to decrease -132.6/spl plusmn/35.7 mg/dL in 60 minutes. After the US and insulin were removed, the blood glucose level of US-Insulin group continued to decrease to -208.1/spl plusmn/29 mg/dL. These results indicate the feasibility of using a low cost, light weight Cymbal array for enhanced transdermal insulin delivery using US.
机译:这项研究的目的是证明使用具有基于transducer换能器的新型,低调的2比2 US阵列的兔子在体内进行US胰岛素的透皮递送。作为实用的装置,the阵列(f = 20 kHz)的尺寸为37 / spl倍/ 37 / spl倍/ 7 mm / sup 3 /,重量不足22g。以相似的强度(I / sub sptp / = 100 mW / cm / sup 2 /,占空比为20%),我们的目标是确定兔子是否可以达到相同的效果。在三组中进行了十四只新西兰白兔(2.7-3.4kg)的实验:两个对照组和一个US暴露于胰岛素。第一组(对照组1)在没有US的情况下将胰岛素放置在储液罐中,而第二组(对照组2)在I / sub sptp / = 100 mW / cm / sup 2 /下运行US的储液罐中的盐水持续60分钟。第三组(US-Insulin)在接受US暴露60分钟(I / sub sptp / = 100 mW / cm / sup 2 /)的情况下接受胰岛素治疗。在实验开始时,使用血糖监测系统从耳静脉收集0.3 mL血液以确定血糖水平(mg / dL)。在暴露60分钟后关闭US后,用阵列将胰岛素储库移除。对于对照1和2,血糖水平在15分钟和30分钟时显示升高,并保持在约+ 50mg / dL。对于美国胰岛素组,发现葡萄糖水平在60分钟内降低了-132.6 / spl plusmn / 35.7 mg / dL。去除US和胰岛素后,US-胰岛素组的血糖水平继续降低至-208.1 / spl plusmn / 29 mg / dL。这些结果表明使用低成本,轻量级的mb片阵列使用US增强经皮胰岛素输送的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号