首页> 外文会议> >Evaluation of delaminated high-voltage rotating machine stator winding groundwall insulation
【24h】

Evaluation of delaminated high-voltage rotating machine stator winding groundwall insulation

机译:分层高压旋转电机定子绕组接地绝缘的评估

获取原文
获取外文期刊封面目录资料

摘要

In recent years, a distinctive nonlinear characteristic of the current versus ramped dc voltage test response has been observed which identifies rotating machines having delaminated stator winding insulation. This characteristic response is described and analyzed. Two illustrative examples of hydroelectric generators with delaminated groundwall insulation are presented. In one case, the ramped voltage test curve is compared against power factor and capacitance versus ac voltage measurements taken on the aged stator winding and on unused spare coils. Results of dissection analyses of aged stator coils removed from the winding and spare coils are also discussed. In the second example, ramped voltage test data are compared to on-line partial discharge measurements.
机译:近年来,已经观察到电流与斜坡的直流电压测试响应的独特非线性特性,其识别具有分层定子绕组绝缘的旋转机器。描述和分析该特征响应。提出了具有分层地基绝缘体的水力发电机的两个说明性实例。在一种情况下,将斜坡电压测试曲线与功率因数进行比较,并且在老化的定子绕组和未使用的备用线圈上采取的AC电压测量值。还讨论了从绕组和备用线圈中取出的老化定子线圈分析结果。在第二示例中,将斜坡电压测试数据与在线局部放电测量进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号