A new non-unit voltage protection algorithm for extra high voltage (EHV) transmission lines is presented in this paper. The singularity of fault transient voltage signals in one terminal is utilized to discriminate clearly between internal and external faults. Lipschitz Exponent (LE) is obtained from wavelet modulus maximum to detect singularity of signals. A typical 500-kV EHV transmission system has been simulated by ATP to evaluate the scheme. The simulation results show that this scheme is capable of providing correct responses under various system configurations and fault conditions.
机译:提出了一种新的超高压输电线路非单位电压保护算法。故障瞬态电压信号在一个端子上的奇异性可用来清楚地区分内部故障和外部故障。 Lipschitz指数(LE)从小波模极大值获得,以检测信号的奇异性。 ATP已对典型的500 kV超高压输电系统进行了仿真,以评估该方案。仿真结果表明,该方案能够在各种系统配置和故障条件下提供正确的响应。