For the gentle and non-destructive characterisation of small tissue samples, non-invasive methods are required for biotechnological applications and medical diagnostics. One approach is the characterisation of small tissue samples by impedance spectroscopy using a measuring capillary. In this paper, the applicability of a capillary measuring system to record the impedance of a biological sample over a wide frequency range is evaluated using a suspension of human breast adenocarcinoma cells (MCF-7). Impedance spectra over a frequency range 1 Hz to 1.1 GHz were recorded. To describe the electrical properties of the cell suspensions, we use an equivalent circuit model containing advanced RC-elements. Changes of plasma membrane integrity of suspended cells were detectable
机译:为了对小组织样本进行温和且无损的表征,生物技术应用和医学诊断需要非侵入性方法。一种方法是使用测量毛细管通过阻抗光谱法对小组织样本进行表征。在本文中,使用人乳腺腺癌细胞(MCF-7)悬浮液评估了毛细管测量系统在很宽的频率范围内记录生物样品阻抗的适用性。记录了在1 Hz至1.1 GHz频率范围内的阻抗谱。为了描述细胞悬液的电特性,我们使用了包含高级RC元素的等效电路模型。可检测到悬浮细胞质膜完整性的变化