Simulation and observer based detection of airgap asymmetries caused by rotor eccentricity in inverter fed AC machines

机译:基于仿真和观测器的逆变器交流电机中由转子偏心引起的气隙不对称检测

获取原文
获取外文期刊封面目录资料

摘要

A new method to detect fault conditions in inverter fed AC machines caused by asymmetries in the airgap is presented in this contribution. In the first part the influence of these asymmetries on the transient electrical behavior of the machine is investigated by simulation results obtained from a magnetic equivalent circuit model. Starting from these results the proposed method is derived. It is based on the reaction of the machine current to voltage pulses caused by the switching of the inverter. The continuous switching of the inverter is necessary for the current control loop during normal operation of the drive. Using a special observer structure any changes in the reaction of the machine caused by airgap asymmetries can be detected and isolated. The only inputs necessary for the realization of the method are the DC link values of the voltage and the current. The observer estimates the transient parameters of the three phases and by comparing the three phase values an error signal can be calculated. The method is insensitive to changes of the machine parameters due to temperature or saturation as long as these changes occur symmetrically in all three phases. The method is applicable in both steady state and transient operation. The practical operation of the method is verified by measurement results at different points of operation and with different fault positions/magnitudes.
机译:该贡献提出了一种新方法,该方法可检测由气隙不对称引起的逆变式交流电机故障状况。在第一部分中,通过从磁等效电路模型获得的仿真结果来研究这些不对称性对电机瞬态电性能的影响。从这些结果出发,得出了所提出的方法。它基于电机电流对逆变器切换引起的电压脉冲的反应。在变频器正常运行期间,对于电流控制回路,必须进行逆变器的连续切换。使用特殊的观察器结构,可以检测和隔离由气隙不对称引起的机器反应的任何变化。实现该方法所需的唯一输入是电压和电流的直流母线值。观察者估计三相的瞬态参数,并且通过比较这三个相位值,可以计算出误差信号。该方法对由于温度或饱和度引起的机器参数变化不敏感,只要这些变化在所有三相中对称出现即可。该方法适用于稳态和瞬态操作。通过在不同操作点和不同故障位置/幅度下的测量结果验证了该方法的实际操作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号