A breakdown time lag of uniform electric field using sphere-sphere electrodes was measured in pure mineral oil and in contaminated oil. The electrodes were steel spheres of diameter 12.5 mm. The effect for breakdown time lag wielded by differences of the distance between electrodes, applied impulse voltage and contaminant was measured, The breakdown time lag increased proportionally to applied voltage and the breakdown time lag of contaminated oil was shorter than the one of no contaminated oil. It was found that the breakdown phenomenon in this experiment was a streamer type breakdown structure.
机译:在纯矿物油和受污染的油中,使用球形-球形电极测量了均匀电场的击穿时间滞后。电极是直径为12.5毫米的钢球。测量了电极之间的距离,施加的脉冲电压和污染物之间的差异对击穿时间滞后的影响,击穿时间滞后与施加电压成正比,污染油的击穿时间滞后比没有污染的油短。发现该实验中的击穿现象是拖缆型击穿结构。